About how to operate plug tester

Plug tester 1. First replace the appropriate test fixture.

2. Connect the trachea regulator pressure regulator, pressure adjustment in the 0.2-0.4MPA, not too large or too small; plug in the power cord, confirm the voltage at 220V.

3. Zero pole and outer high-voltage knob (voltage reset to safety)

4. According to whether the wire is single-headed or double-headed, select 2PIN, 3PIN switch and single head, double head switch, switch in D position, representing double head test, switch in S position, representing single head test,

5. According to whether the polarity of the wire should be tested and set to have polarity, non-polarity switch, the switch is placed in the POL representative polarity test, and the switch is placed in the VON representative conduction test, ie there is no polarity test.

6. Set the positive or reverse polarity switch according to the position of the live wire and the neutral wire in the wire. (Note: The positive and negative polarities are relative and there is no formal requirement. What is positive and what is negative can be verified with the verification machine's good product line. If the positive polarity and the machine show good quality, This indicates that the wire is positive polarity: if it shows a poor polarity, it means that the wire is reverse polarity and should be set to reverse polarity.)

7. Insert the plug, the power cord will constitute a loop, the product of internal and external high voltage, leakage current, exposed copper test, after passing the test function of the master cylinder are all qualified, the main cylinder return push plug and marked and record the number of test At the same time, the tester triggers the magnetic switch and resets it to the initial state. Any faults have sound and light alarms. At the same time, the clamps are clamped to prevent defective products from flowing into good products. Only press the reset button to release the clamp and remove the defective product.

8. When the non-conduction phenomenon occurs, the machine is not mode-locked, and the input high-pressure lamp is not displayed. When exposed copper, short-circuit, polarity, and withstanding voltage phenomena, the machine locks the mold at the same time, press the red reset button, remove the plug Bad label, put in red box;

9. During the operation process, the machine is inspected and recorded with an inspection sample every hour. If an instrument abnormality is found during the inspection, the tester must be repaired, and the product is retested after the previous inspection. .

10. After the test is completed, reset the high pressure in the pole and the outside, and then turn off the power.

11. According to the safety requirements of the wire, customer requirements or internal company requirements set parameters. (Including: On resistance, leakage current, external high voltage, test time.)

12. Length setting Dial indicator value: If the test is on, you must set the length adjustment at 100%, which is a polarity test and should be adjusted to zero.

13. Turn on the high-voltage start switch, turn the start switch to the right, and turn on the high pressure, ready to enter the high pressure test.

14 Set up the above test items, check the instrument with the inspection model, and start the test after the equipment is qualified.